 Chịu được nhiệt độ lên đến 2000C    
- Chiều dài có thể cắt theo yêu cầu    
- Đầu ra có thể lên tới 50W/m      
- Phạm vi điều khiển rộng, đầy đủ phụ kiện, tiêu chuẩn rộng
- Có sẵn loại  220 - 277V AC (110 - 120V AC on request)
  • Thông tin sản phẩm
  • Bình luận

IPL is a constant wattage heating tape that can be used for freeze protection or maintenance of process temperatures in pipework and vessels.
It can be cut-to-length at site and can replace mineral insulated (MI) cables for applications where the cut-to- length feature or field fabricated heating cable is preferred.
IPL is approved for use in non-hazardous areas.
Because of the special construction with “heating zones” no additional cold lead is needed. From cut point to the next heating wire bonding point the heating cable remains cold and serves as cold lead.
The installation of IPS heating tape is quick and simple and requires few special skills or tools. Termination and power connection components are all provided in convenient kits.

Options

IPL… Basic heating tape without braiding and without outerjacket.
IPL…C Tinned copper braid providing mechanical protection or where traced equipment does not provide an effective earth path. eg. plastic pipework.
IPL…CT Thermoplastic outerjacket over tinned copper braid provides additional protection.
IPL…CF Fluorpolymer outerjacket over tinned copper braid provides protection where corrosive chemical solutions or vapours may be present.
Technical Data Maximum Pipe / Workpiece Temperature
Maximum Temperature: 300°C (Un - Energized)   The surface of the heater must not exceed the maximum withstand temperature of its constructional materials or the Temperature Classification (if installed in a hazardous area). This is ensured by limiting the pipe or workpiece temperature to a safe level either by design calculation (a Stabilised Design) or by means of temperature controls.
For worst case conditions, the temperature of steel pipes should be limited to the following levels
Max Operation Temperature: see table  
Minimum Insallation Temperature: -80°C  
Power Supply: 220-240V AC  
Max. Resistance pf Protective Braiding: ≤ 18,2Ohm/km  
Weights and dimension: Output (W/m) Maximum pemissible pipe temp ( ̊C)
Type Nom Dimensions (mm) Weight Kg/100m Min. Bending (mm) Gland size TPL… IPL..C IPL…CS IPL…CF
6.5 190 190 190 190
IPL… 8,2 x 7,0 7,4 10 M16 13 180 180 185 185
IPL…C 9,0 x 6,8 11,7 12 M16 23 150 150 160 160
IPL…CS 11,0 x 8,8 14,3 15 M20 33 110 110 115 115
IPL…CF 10,2 x 8,0 14,3 25 M20 50 70 75 80 75
Construction Maximum Circuit Length
Heating Element: Nickel-Chromium Output (W/m) Max.Circuit Length Zine Leght
Power Conductors: Tin Plated Copper 1,5mm² 115V 230V 115V 230V
Conductor Insulation: Silicone Rubber 6.5 82m 164m 1000mm 1500mm
Jacket: Silicone Rubber 13 58m 116m 741mm 1100mm
Braid: Tinned Copper 23 44m 87m 900mm 1000mm
Over Jacket: Silicone Rubber or Fluoropolymer 33 36m 73m 1000mm 950mm
  50 30m 59m 995mm 900mm
For conditions other than worst case, or pipes of other materials, consult Quintex
Ordering Information Power Conversion Factors
  115V Heating 230V Heating Tape
277V Factor 5.80 277V Factor 1.45  
230V Factor 4.00 240V Factor 1.09  
208V Factor 3.27 220V Factor 0.91  
120V Factor 1.09 208V Factor 0.82  
110V Factor 0.91 115V Factor 0.25  
Accessories Further Information
Quintex offers a complete line of accessories, temperature controller, connection sets as well as different enclosures. These products are recommended for a failure free operation Please consult the appropriate termination instructions and the installation manual.