Danh mục sản phẩm
Khả năng chống tia UV cao | |||||
- Sẽ không quá nhiệt hoặc cháy, thậm chí cả khi chồng chéo | |||||
- Chiều dài có thể cắt theo yêu cầu | |||||
- Lắp đặt dể dàng | |||||
- Có sẵn loại 220 - 277V AC (110 - 120V AC on request) |
Quintherm CLD is a special self-limiting heating cable for gutter heating and to prevent formation of snow slab on roofs areas.
Thanks to the UV resistance, these heating tapes are well suitable to the requirements of this particular application. By the temperatur resistance of 85°C this heating tape resists even hot surfaces caused by sun exposure.
Its self-regulating characteristics improve safety and reliability. Quintherm CLD will not overheat or burnout, even when overlapped. The power output is self- regulated in response to the ambient temperature.
On the characteristics can be seen that the heating tape can reach a power output of 36W/m in ice water to ensure the required defrost ability.
Possible applications
Gutter heating |
Roof valley heating |
Downspoat heating |
Roof area heating |
Roof drain heating |
Facade heating |
Technical Data | Max. Length (m) vs. Circuit Breaker Size | |||||||||
Max. Allowed Temperature: | Energized 85°C | Type | Start-up Temp. | 10A | 16A | 20A | 30A | |||
De-Energized 85°C | CLD182CT | 10°C | 56 | 88 | 92 | - | ||||
Min. Installation Temperature: | -40°C | 0°C | 48 | 76 | 92 | - | ||||
(CENELEC -20°C) | ||||||||||
Power Supply: | 220-277V AC | -20°C | 36 | 58 | 74 | 92 | ||||
Maximum Resistance Of Protective Braiding: | ≤ 18,2Ohm/km | |||||||||
Type | Nominal Dimensions (mm) | Weight Kg/100m | Min. Bending Radius (mm) | Gland size | Power Output Multiplying Factors | |||||
Supply Voltage | Multiplying Factor | |||||||||
CLD | 10,5 x 5,9 | 10,0 | 35 | M20 | 200V | 0,91 | ||||
Power Output | 208V | 0,93 | ||||||||
220V | 0,97 | |||||||||
In air at 0°C: | 18W/m | 230V | 1,00 | |||||||
In ice water: | 36W/m | 240V | 1,03 | |||||||
250V | 1,06 | |||||||||
277V | 1,15 | |||||||||
For use with Typ C circuit breakers to EN60898 |
Cold Start Data | Thermal Ratings | ||
Start at °C | Current (A/m) at 230V AC | Nominal output at 230V AC | |
-20°C | 0,272 | W/m | |
0°C | 0,212 | ![]() |
|
+10°C | 0,180 | ||
Accessories | Ordering Information | ||
Quintex supply a complete range of accessories including termination/splice kits, end seals, junction boxes and controls. Such items carry separate approvals from the heating tapes. When used in hazardous areas, only use approved components. | ![]() |
![]() |
234/7 Vườn Lài, P. Phú Thọ Hòa,Q.Tân Phú, TP. Hồ Chi Minh |
![]() |
Tel: 028.3978.2976 - 0888.183.943 Fax: 028.3978.2977 |
![]() |
sales@vtech-electric.vn |
![]() |
www.vtech-electric.vn |
![]() |
P.602, S-Home Building, 110A Đường 30/4, Q. Hải Châu, Đà Nẵng |
![]() |
Tel: 023.6384.3554 Fax: 023.6384.3455 |
![]() |
sales@vtech-electric.vn |
![]() |
www.vtech-electric.vn |
![]() |
P.201, 63 Vũ Ngọc Phan, P. Láng Hạ, Q. Đống Đa, TP. Hà Nội |
![]() |
Tel: 024.3775.7157 Fax: 024.3775.7154 |
![]() |
sales@vtech-electric.vn |
![]() |
www.vtech-electric.vn |